DASYLab New Features - 2016

DASYLab New Features

dasyvista_smWhat’s New in DASYLab 2016

Better precision
The internal data format for both, data acquisition as well as for further processing was changed from „float“ to „double“. Although previously already a variety of hardware was supported, now this profound modification of the whole DASYLab structure allows the full support of the capabilities of high- resolution measurement hardware with a significantly increase accuracy.

Larger max. block size
The block size, an important parameter in data processing and analysis, has been limited to 32k values. The values can be increase in the new version to 1 Mega-Samples. Especially with block-related operations such as FFT, the resolution and accuracy increases significantly. Likewise thereby the user benefits from improved support, faster measurement technology and optimized channel multiplexing.

New sequencer module
The new sequencer module processes sequences with far less modules than in older DASYLab versions. Previously such applications were built with a combination of action modules, trigger modules, relays and connections. The processes are much easier to create and maintain because the steps can be inserted, deleted or changed in order within the module. Not only is the creation of the processes with DASYLab accelerated, but the finished worksheet also requires less computing time and memory.

Conversion of the standard data format
Besides the DASYLab DDF format now TDM and TDMS format will equally be standard (known from DIAdem and LabVIEW) and supported reading and writing. Herewith the compatibility with other National Instruments products will increase. Of course the DDF format has been extended so that it supports the lager blocks and higher accuracy.

Some more new improvements

  • Switch position at the start of measurement is now selectable.
  • The output values for switch position on and off can be fixed (double)
    • In the input fields variables can be entered
    • Changed variable values are taken into account during measurement
  • The input values for ON / OFF can be selected by action.
  • Display module: y/t and XY graph
    • The line type „Pixel“ was added to the module

Hier geht es weiter

Was sagen unsere Kunden über uns?

Your technicians are always really friendly, reassuring and helpful.

HM, Cambs, UK

I greatly appreciated the fact that you did what you said you would do – not everyone is so nice and punctilious as you.

Dr PL, Kent, UK

I like thinking back to all the people I’ve worked well with during the year, and you have been particularly helpful throughout.

HM, Durham, UK

Very helpful in providing advice on which courses were applicable. Very clear. Checked with trainees to ensure the pace was accurate. Very aware of individual needs of trainees without letting individual issues take over. My interaction with Adept has always been very good. Staff are helpful, efficient and responsive.

Dr C Stott, Cambridge, UK

Zur Zeit ist es uns leider nicht möglich die folgenden Produkte anzubieten. Wir arbeiten jedoch daran Ihnen ein möglichst vielfältiges Produktsortiment zur Verfügung zu stellen. Bitte kontaktieren Sie uns wenn Sie Fragen oder Anregungen haben.