Zuletzt geändert 10th Jan 2013
Category:  > DASYLab
Version: All
Article Ref.: 13C26
»Zurück zur letzen Suche
»Print friendly version of this article.
1 person has found this article useful.
DASYLab 13C26 To set up the configuration of the installed Datascan 7000 Measurement Processor, go to the Experiment/Measurement menu and select "Hardware Setup." The Datascan 7000 driver creates a file called Datascan.Ini which contains the stored configuration. The default location for this file is the WINDOWS path (for example C:\Windows on XP or C:\Winnt on 2000.) If the configuration that you set up is not retained when DASYLab is closed, then there may be a problem creating the DATASCAN.ini file. Go to the Windows folder and check that you have write access to that folder. Check for the DATASCAN.ini file and if found, delete it then restart DASYLab in case this file was corrupted. How Do I? DASYLab All en DASYLab

Wenn Sie technische Fragen zu Soft- und Hardware haben, die bei uns erworben wurde, dann verwenden Sie dazu bitte unsere Knowledge Base. Falls Sie keine Antwort in unserer Knowledge Base finden, dann fllen Sie bitte hier das Formular fr Technischen Support aus oder rufen uns an unter +49 69 9675 9610 (werktags von 9 bis 13 Uhr).